Furnace Repair in Los Altos, CA
If your furnace will not light in Los Altos, the most likely answer is ignition or airflow, not a dead furnace. The oldest system on my Los Altos service list went in in 2014 and the newest in 2022, so the heating equipment I get called to here is not old. It is electronically controlled equipment where one sensor, one igniter or one switch has stopped doing its job.
One caveat specific to this city, and I will come back to it. If you live in an Eichler with a flat roof and a heated slab floor, you may not have a furnace at all. Booking a furnace repair for a radiant slab wastes your morning and mine.
I am John Towner. I own Silicon Valley Comfort, I have been in this trade 25 years, I do the work myself, and you can reach me at 408-691-5940.
Why furnace repair in Los Altos is its own job
Gas furnaces are one of the three equipment types that come up most on my own Los Altos jobs, alongside evaporator coils and condensers. That is my book of work, six jobs deep, not a survey, so take it as what I keep running into rather than a statement about your block.
The brands on that list are Bryant, ADP and Payne. Bryant and Payne share a parts family, which means igniters, pressure switches, inducer assemblies and control boards cross between them, and I can stock the common ones instead of chasing a part while your house gets cold. I work as an Independent Bryant Installer, so those boards and their flash codes are familiar ground.
The install years matter more on heating than they do on cooling. A furnace put in between 2014 and 2022 has a hot surface igniter, an inducer motor, at least one pressure switch, and a control board that flashes a fault code at you through the sight glass. It does not have a standing pilot. If you have been kneeling in front of the unit hunting for a pilot light to relight, there is not one to find, and that is not what is wrong.
The systems on my list here run from 2 tons up to 5 tons, so there is no standard machine and I read the rating plate on yours.
What actually fails on a Los Altos furnace
Three faults account for most of the no heat calls I get on furnaces of this vintage.
The flame sensor. This is a single metal rod sitting in the flame, and its whole job is to prove to the control board that there is fire. It builds an oxide film over a few seasons and stops passing enough current, so the board does exactly what it should and shuts the gas off. The furnace lights, you hear it running, and four to seven seconds later it drops out and starts the sequence over. On a furnace built in the last decade that is the single most common no heat cause I find, and it is often a cleaning rather than a part.
The hot surface igniter. Every furnace of this age has one, and it is brittle ceramic shocked to glowing on every cycle. They crack. When one fails you get the inducer starting, then a long pause, then nothing, and the board will flash a code telling you so.
The pressure switch that will not close. This gets misdiagnosed constantly, and the switch is usually telling the truth. It is a safety that refuses to let the furnace fire until it senses the inducer actually pulling. When it will not close, the real problem is nearly always upstream of it. A blocked condensate trap on a high efficiency unit, a plugged pressure port, a restricted flue, or an inducer losing speed. Replacing the switch without finding out why it would not close puts you back where you started, usually on a colder night.
The Furnace In The Hall Closet
In a typical Los Altos ranch home, the furnace lives in a hall closet with a return grille in the door or the wall beside it. It is easy to reach, and it is also easy to starve. Closets get used for storage, louvered doors get replaced with solid ones, and the return grille ends up half blocked by a vacuum cleaner. A furnace that cannot pull enough air overheats, trips its high limit, and shuts off before the house warms up.
Furnace repair in Los Altos often starts at that closet door. Clearing the return path and checking the filter size against what the furnace needs fixes more no heat calls than most people would guess.
Older Furnaces And Heat Exchangers
Plenty of Los Altos furnaces are twenty years old or more. The heat exchanger, the metal chamber that keeps combustion gases separate from the air you breathe, is the part that ages most dangerously. Years of overheating from restricted airflow crack it. A cracked heat exchanger can let combustion gases into the airstream, and it can also cause flame rollout, where the flame curls out of the burner area and trips the rollout switch.
Every furnace call includes a heat exchanger inspection, a look at the flue, and a combustion test. When a heat exchanger is cracked, the furnace stays off until it is replaced. That is not a sales pitch. It is the one repair that cannot wait.
Remodels And The Undersized Furnace
When a Los Altos home adds a family room or second story, the original furnace and ducts often get stretched to cover it. The new rooms run cold, the furnace runs long, and the duct runs to the addition are too small or too far from the furnace. A load calculation for the house as it stands now shows whether the furnace is truly too small or whether the ducts are the bottleneck. Often a duct change fixes what a new furnace never would.
Simple Steps Before You Call
Check the filter, make sure the furnace closet door and return grille are clear, and confirm the furnace switch is on. If the furnace lights and then shuts off after a few seconds, note any blinking codes on the control board. A dirty flame sensor is a very common cause, and it is a quick fix. Every home with gas appliances should have working carbon monoxide alarms on each level and near the bedrooms. If an alarm sounds, get everyone outside first and call from there.
A yearly furnace check before the first cold night is the simplest way to stay ahead of all of this. The flame sensor gets cleaned and measured, the igniter gets tested against its spec, the filter and return path get checked, the drains get cleared on high efficiency furnaces, and the combustion and temperature rise readings get recorded. Next year, those numbers become the comparison that tells us whether anything has started to drift.
It is a short visit that heads off most mid winter failures.
Book it in the fall, before the rush.

When you book, mention where the furnace is, whether the house has been remodeled, and which rooms run cold. If the furnace lights and shuts off quickly, note the blinking code on the control board. And if anyone in the house has noticed headaches that ease when they leave, turn the furnace off and say so when you call, so the visit starts with a combustion check.
How I diagnose it
First I read the flash code on the board, because the furnace has already been keeping notes on itself. That tells me where to start, not what to replace.
Then the meter. Flame sensor microamps is the reading that settles the most common fault on the list. A clean rod in a good flame gives a number. A rod that has been cleaned and still will not give it is telling me the problem is the flame or the board, not the sensor, and that is the difference between a five minute fix and a real repair.
I check gas manifold pressure against the rating plate on your furnace, not against a number I remember. Overfired and underfired both cause trouble and both look like something else from the outside.
The reading that catches the most misdiagnosed furnace in the trade is temperature rise across the heat exchanger, measured against the range printed on the plate. A furnace running above that range is usually not broken at all. It is a furnace that cannot move enough air, from a loaded filter, a crushed flex duct or a blower not making speed. That is what trips your limit switch and shuts you down every fifteen minutes.
I read inducer and blower amp draw when the symptoms point that way.
If I find a cracked heat exchanger I will tell you, I will show you, and I will shut the furnace down. That is not a sales move. That is combustion products in the air you breathe.
Repair or replace
Start with the honest case for not calling me.
Check the filter. Check that the furnace door panel is fully latched, because there is a switch behind it and a furnace with the panel loose will not run at all. Check the thermostat batteries and that it is set to heat. Check the breaker. And check that nobody working on something else has closed the gas valve on the pipe. All of that is free, and it ends more no heat calls than people expect.
Then check whether the equipment is still inside its original manufacturer parts warranty and whether anyone registered it. That will not cover labor, but it can cover the part, and you should know before you pay anyone, including me.
Now the repair side. A furnace installed between 2014 and 2022 is not a replacement candidate just because it quit. Igniters, sensors, switches, inducers and boards for that generation are all still in production, and flame sensors are frequently a cleaning rather than a purchase.
The genuine replace triggers are short. A cracked heat exchanger ends the conversation and I will not repair one. A control board plus an inducer plus a blower motor in the same season is money going the wrong way. And if the house is an Eichler where the heat is in the slab and the slab loop has failed, replacing a furnace is not even the question in front of you. That one usually ends up going to a ducted or ductless heat pump, because a flat roof with no attic gives you nowhere to put a conventional furnace.
Los Altos neighborhoods I cover
Neighborhood names matter less to a heating call in Los Altos than one structural question. Where does the furnace live.
On a postwar ranch on a large lot it is in the attic or a hall closet. An attic install means the ductwork runs through unconditioned space, so heat leaks out of the supply runs before it reaches the room, and a house that feels underheated is sometimes a duct problem wearing a furnace costume. It also means access. On a cold morning a real part of the work is getting to the equipment, so tell me on the phone if the hatch is in a closet behind boxes.
An Eichler has no attic at all. Flat roof, radiant slab, heat coming up through the floor rather than out of a register. That is not a furnace, and a furnace repair will not help you.
North Los Altos, Downtown Los Altos, Country Club and the Highlands are all a short drive apart for me. The address is not the variable. The building is.
Straight Pricing, No Surprises
Residential Diagnostic
$99
Standard hours. After 6:00 PM, Saturdays, and holidays: $149. The standard diagnostic is credited toward your repair if you approve the work on the same visit.
Commercial Diagnostic
$199
Business hours. After-hours: $299. Light commercial, retail, and multi-family equipment.
Repairs and Installations
Quoted before we touch a wrench. Supplier invoice attached to your job sheet.
Furnace Repair Los Altos: common questions
My furnace lights and then shuts off after a few seconds. What is that?
That is the classic dirty flame sensor pattern. The furnace proves ignition, the sensor fails to confirm flame, and the board shuts the gas off as a safety. It is the most common no heat cause I find on furnaces of this age, and often a cleaning rather than a part. If cleaning does not hold, the next suspects are the flame or the board, and telling those apart takes a microamp reading.
There is no pilot light on my furnace. Is that the problem?
No. A furnace installed between 2014 and 2022 does not have a standing pilot. It has a hot surface igniter that glows on demand, and there is nothing for you to relight. If it is not firing, the board is almost certainly flashing a fault code through the sight glass. Count the flashes and tell me the pattern when you call. It often tells me which part to bring.
I live in a Los Altos Eichler with heated floors. Can you help?
Tell me that before anything gets booked. Radiant slab heat is not a furnace, so a furnace repair call will not solve it. In those houses, once the slab system is no longer worth chasing, the practical path is usually a ducted or ductless heat pump, because a flat roof with no attic leaves nowhere to put a conventional furnace. Better to have that conversation on the phone than after I have driven out.
My furnace runs about fifteen minutes, shuts off, then restarts. Why?
That is usually the high limit switch doing its job because the furnace is getting too hot, and the reason is nearly always airflow. Loaded filter, closed registers, a crushed flex duct, or a blower not making speed. I measure temperature rise across the heat exchanger against the range on the rating plate to prove it. Replacing the limit switch on a furnace like that fixes nothing.
Is a furnace installed around 2015 worth repairing?
Almost always yes. Parts for that generation are still in production, and one failed sensor or igniter does not make a furnace obsolete. The exception is a cracked heat exchanger, which I will not repair and which ends the discussion. If I find one I will show it to you and shut the unit down.
Can I reach you at night?
I am available 24/7 at 408-691-5940 and it is me answering. I will not hand you an arrival time before I know what else is running, but I will tell you honestly when I can get there rather than taking the booking and leaving you wondering.