Furnace Won’t Ignite What fails, in the order the furnace checks it
A furnace does not just turn on. It runs a checklist first: draft proven, igniter hot, gas open, flame confirmed. When it will not light, it is stopping at one specific step, and the step tells you what failed. Here is how to read it, what you can safely check yourself, and where we take over with meters.
No Heat, Narrowed Down
Most no heat calls come down to three parts and one dirty filter. The skill is proving which one before anything gets replaced.
What It Is Doing Tells You Where It Stopped
Stand at the furnace during a call for heat and watch. What happens, and what does not, points at the step that failed.
Nothing happens at all
No fan, no click, no lights. Usually no power or no signal: a tripped breaker, the furnace switch off, a loose door, a blown low voltage fuse on the board, or a thermostat that is not actually calling.
A small fan runs, then nothing
That fan is the draft inducer. If it runs and nothing follows, the pressure switch never proved draft. Think blocked vent, cracked hose, plugged port, or on a condensing furnace, a drain that is backed up.
No orange glow
On most furnaces a hot surface igniter should glow bright orange within a minute of the inducer starting. No glow with draft proven usually means a cracked igniter. They are brittle and they do wear out.
It glows, but no flame
The igniter is doing its job and no gas is arriving. That is a gas valve that did not open, a closed shutoff, or no gas reaching the furnace at all.
It lights, then quits in seconds
The burners light and drop out within about five seconds. The furnace lit but could not prove it. That is the flame sensor circuit, and most of the time the sensor is just dirty.
Clicking and a flashing light
The control board is retrying and reporting a fault code with its light. Count the flashes through the little window before you open the door. On many furnaces, opening the door cuts power and erases the code.
How We Diagnose A No Ignition Call
We follow the same sequence the furnace does and measure at each step. The first reading that is wrong is the fault.
Check It Yourself Or Stop And Call
Some of this is safe for anyone. Some of it involves gas and a safety that tripped for a reason.
Safe to check yourself
- Thermostat set to heat, set above room temperature, with fresh batteries
- Furnace power switch on. It looks like a light switch and gets bumped off constantly
- Breaker on, and the furnace door fully seated on its safety switch
- A clean filter, and supply registers open through most of the house
- Gas shutoff handle at the furnace in line with the pipe, and the flash code written down
Stop and call
- You smell gas. Leave the house and call the gas company from outside
- A rollout switch has tripped. Do not reset it. Flame went somewhere it should not
- You see scorch marks, melted wire, or soot around the burner compartment
- It locks out again after you reset the power once
- A carbon monoxide alarm has sounded at any point
What A Visit Costs
You get the full price in writing before any work starts, and you approve it. Nothing appears on the invoice that you did not agree to.
How A No Heat Call Runs
You call John
Tell us what the furnace does when it tries. Fan or no fan, glow or no glow, and the flash code if you have it.
Measured in order
We follow the ignition sequence with a meter and a manometer and stop at the first reading that is wrong.
You see the price
The fault, the fix, and the full price in writing before any part goes in.
Proven working
Several clean cycles from the thermostat, readings rechecked hot, and combustion tested before we leave.
The Checklist A Furnace Runs Before You Get Heat
Modern furnaces light in a fixed order, and the control board refuses to move to the next step until the current one is proven. That is why watching it tells you so much.
- The thermostat calls for heat and the board checks that its safeties are in the right starting position
- The draft inducer starts and pulls air through the heat exchanger and out the vent
- The pressure switch closes, which proves the vent is actually moving air
- The igniter heats up, or on some furnaces a spark starts
- The gas valve opens and the burners light
- The flame sensor confirms flame within a few seconds, or the board shuts the gas off
- The blower starts once the heat exchanger is warm
If any step fails, the board stops, waits, and tries again. After about three failed tries it locks out, often for an hour or more, and that is the dead furnace you wake up to.
The Three Parts Behind Most No Heat Calls
The hot surface igniter is a ceramic element that glows at well over two thousand degrees every single time the furnace starts. It is a wear item. They crack, and a cracked igniter will sometimes still glow, just not hot enough to light gas on a cold morning.
The flame sensor is a plain metal rod sitting in the flame. The board passes a tiny current through the flame to that rod to confirm the burners are lit. A thin coat of oxide on the rod is enough to block the signal, so the furnace lights and then shuts itself off as if nothing happened. Cleaning it correctly fixes most of these. Finding out why it got that dirty is the rest of the job.
The pressure switch is a safety that proves the vent is clear before gas is allowed to flow. When it will not close, the switch itself is the least likely cause. A bird nest in the vent cap, a sagging vent run holding water, a cracked rubber hose, or a condensate trap full of sludge will all hold it open.
When It Is Not The Furnace At All
Some no heat calls end at the gas meter. Earthquake shutoff valves are common here, and they can trip from a jolt you slept through or a bump from a trash can. If the stove and the water heater are dead too, look there first. A thermostat with weak batteries, or a smart thermostat starving for power, will also keep a healthy furnace from ever getting the call.
Why Guessing Gets Expensive
Every one of these symptoms has at least three possible causes, and the parts are easy to swap, so a lot of furnaces get repaired by trial and error. An igniter goes in, then a flame sensor, then a board, and the real problem was a loose ground the whole time. We would rather spend twenty minutes measuring and replace one part than be right on the third try.
Why A Furnace Won’t Ignite On The First Cold Night
In the South Bay a furnace sits idle from about April to late October. Nothing fails while it sits, but everything marginal gets a little worse. The flame sensor grows a film of oxide. Dust settles on the burners. Spiders move into the burner orifices and the pressure switch hose. On a condensing furnace the drain trap dries out or grows a plug of sludge. Then the first cold night arrives, half the valley turns the heat on in the same hour, and every weak igniter in the county gets found at once.
The cheap insurance is a test run. Pick a mild afternoon in October, set the thermostat to heat, and let the furnace run a full cycle. A dusty smell for the first few minutes is normal. If it will not light, you found out on a Tuesday afternoon instead of at eleven on a cold Saturday night.
What The Flash Code Is Actually Telling You
The control board does not name a bad part. It names the step that failed. On many Bryant and Carrier furnaces the code is two digits, short flashes first and long flashes second. Code 31 means the pressure switch did not close. Code 33 is an open limit or rollout circuit. Code 34 means the burners lit and flame was never proven, and 14 is the lockout that follows several failed tries. The legend printed inside the furnace door is the authority for your model.
Notice that none of those codes say replace the igniter. A 34 can be a dirty flame sensor, a poor ground, or low gas pressure. The code tells us where to put the meter first. It does not do the measuring.
Hot Surface, Spark, Or Pilot
Not every furnace lights the same way. Most built since the 1990s use a hot surface igniter. Some use a spark that lights the burners directly, and some light a small pilot first and prove it before the main gas opens. A furnace with a pilot that burns all year is older still and runs on a thermocouple instead of a control board. The symptoms overlap, but the tests are different, which is one more reason the parts counter is a poor place to start when a furnace won’t ignite.
Where We Work
Silicon Valley Comfort covers San Jose, Los Gatos, Campbell, Saratoga, Cupertino, Sunnyvale, Santa Clara, Monte Sereno, Los Altos, Mountain View, Milpitas, and Morgan Hill, plus San Mateo County and the Santa Cruz mountains. If you are not sure whether we reach you, call and ask. It is a short answer.
Furnace Ignition Questions
Why does my furnace click but not ignite?+
Can I clean the flame sensor myself?+
How long does a furnace igniter last?+
Why does my furnace start and then shut off after a few seconds?+
How do I reset my furnace?+
Is it safe to keep trying to restart it?+
My furnace has a pilot light. Is this the same problem?+
Do you come out at night for no heat?+
No Heat Tonight? Call.
Tell us what the furnace does when it tries to start. Most ignition faults are found and fixed on the first visit, and you see the price before the part goes in.